EVACT=OFF
Event Control
EVACT | Event Action 0 (OFF): Event action disabled 1 (RETRIGGER): Start, restart or retrigger TC on event 2 (COUNT): Count on event 3 (START): Start TC on event 4 (STAMP): Time stamp capture 5 (PPW): Period catured in CC0, pulse width in CC1 6 (PWP): Period catured in CC1, pulse width in CC0 7 (PW): Pulse width capture |
TCINV | TC Event Input Polarity |
TCEI | TC Event Enable |
OVFEO | Event Output Enable |
MCEO0 | MC Event Output Enable 0 |
MCEO1 | MC Event Output Enable 1 |